BCJVK - 624 650T CYLINDER OIL 1000

  • MSDS: BCJVK
  • Manufacturer: TEXACO INC
  • Product Name: 624 650T CYLINDER OIL 1000
  • National Stock Number: 9150-00N003349
Product Identification

Product ID:624 650T CYLINDER OIL 1000
MSDS Date:01/01/1985
FSC:9150
NIIN:00N003349
MSDS Number: BCJVK

Responsible Party
TEXACO INC.

Emergency Phone: 914-831-3400 EXT406

Cage: 38431

Contractor
TEXACO INC
509 BEACON, NY 12508-0509 US

Telephone: 914-831-3400

Cage: 7B131

Ingredients

MINERAL OIL (EXPOSURE REGULATED AS 'OIL MIST')

CAS: 8012-95-1

RTECS: PY8030000

Fraction By Weight: 91%

OSHA PEL 5 MG/M3

ACGIH TLV: 5 MG/M3/10 STEL;9192


METHACRYLATE COPOLYMER

Fraction By Weight: 4%


TALLOW OIL, ACIDLESS

Fraction By Weight: 5%


SILICONEANTI-FOAMANT

Fraction By Weight: <1%


ADDITIVES (COMBINED W/PHOSPHATE & NITROGEN EQUAL 0.1%)

Hazards

Effects of Overexposure:EYES:MINIMAL IRRITATION.INH:MINIMAL IRRITATION.
SKIN:MINIMAL IRRITATION

First Aid

First Aid:EYES:FLUSH W/ WATER FOR 15 MINUTES. SKIN:WASH W/SOAP & WATER.
INH* MOVE INDIVIDUAL TO FRESH AIR.

Fire Fighting

Flash Point:540F; 282C, COC
Extinguishing Media:WATER SPRAY, DRY CHEM, FOAM, OR CO*2.
Fire Fighting Procedures:WATER OR FOAM MAY CAUSE FROTHING.,SCBA,PROTECT
CLOTH.
Unusual Fire/Explosion Hazard:HEAT OR COMBUSTION MAY RELEASE ALDEHYDES,
KETONES, AND OXIDES OF NITROGEN AND SULFUR, CO AND CO*2.

Accidental Release

Spill Release Procedures:CONTAIN SPILL. ABSORB B W/INERT POROUS
MATERIAL

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR IF REQUIRED
Ventilation:NORMAL VENTILATION SUFFICIENT TO KEEP BELOW TLV
Eye Protection:FACE SHIELD GOGGLES.
Supplemental Safety and Health
VP:NIL. % VOLATILE:NIL. TLV:5 MG/CUM FOR MINERAL OIL MIST AVERAGED OVER
8 HR EXPOSURE (MFR).N/D:NOT DETERMINED.

Chemical Properties

Boiling Pt:B.P. Text:N/D
Spec Gravity:0.916
Evaporation Rate & Reference:N/D
Solubility in Water:INSOLUBLE
Appearance and Odor:OPAQUE, GREEN LIQUID

Stability

Hazardous Decomposition Products:HEAT RELEASES
ALDEHYDES,KETONE,NITROGEN & SULFUR OXIDIES,CO.

Disposal

Waste Disposal Methods:MFR RECOMMENDS CONTACTING A WASTE OIL CONTRACTOR
OR DISPOSAL SPECIALIST. ALL MATERIAL MUST BE DISPOSED IAW
FEDERAL,STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.